See what our customers say about us
Your opinion is very important to us.
Let us hear what you think about us!
Reviews
Excellent Service
Jan -
Santa Rosa Beach, FL 32459
Brandon C. from Peaden came out to my home to perform a Spring/Summer check of my Air and Heat System. He was knowledgeable, courteous and worked efficiently! I was very satisfied with his work.
Santa Rosa BeachFL32459 30.39-86.225



Great service and friendly technician
David -
Gulf Breeze, FL 32563
Gulf BreezeFL32563 30.395-87.09




Very Knowledgeable and Friendly Service
Charles -
Shalimar, FL 32579
ShalimarFL32579 30.435-86.5825




Completely satisfied
William -
Lynn Haven, FL 32444
Good efficient work
Lynn HavenFL32444 30.2375-85.6175



Awesome Bidding process
Donna -
Panama City, FL 32408
Herzel was informative, knowledgeable, and polite.
Panama CityFL32408 30.14-85.7525



Owner
Heather -
Panama City, FL 32405
Panama CityFL32405 30.2075-85.6925




Scheduled smart care service
Gary -
Crestview, FL 32539
Received a notification from Peadon A/C this morning and was able to schedule same day service inspection. Jim was very knowledgeable and professional. He explained the steps being taken and identified things we need to keep an eye on. Thanks for being so professional.
CrestviewFL32539 30.7225-86.535



Good service
Pete -
Panama City Beach, FL 32413
Very friendly, polite, and respectful.
Panama City BeachFL32413 30.2425-85.925



Quick Service
MrsRobin -
Pensacola, FL 32526
Dennis is a great service tech with Peaden. He got the job done in a short amount of time and let me know the results of the flush as soon as he was done.
PensacolaFL32526 30.445-87.3175



Great service
Linda -
Fort Walton Beach, FL 32547
Fort Walton BeachFL32547 30.44-86.62




Great service!
Ricky -
Panama City Beach, FL 32408
Herbal Ayala is a courteous, personable young man. He took care of our plumbing issues, explained everything to be done and all that with a smile!
Panama City BeachFL32408 30.1525-85.7225



Joy
Joy -
Panama City, FL 32401
Jason Caputo was efficient & punctual
Panama CityFL32401 30.1725-85.6875



Great service
Eric -
Santa Rosa Beach, FL 32459
Professional
Santa Rosa BeachFL32459 30.405-86.2225



Awesome guys
James -
Panama City, FL 32401
Panama CityFL32401 30.1475-85.6425




Weekend service for clogged hvac condensate line
Dirk -
Rosemary Beach, FL 32461
Rosemary BeachFL32461 30.2925-86.055




Peaden Air Condition .
Upon arrival found drain line clogged flushed drain line checked system operation ever Is working properly at this time
Jamie B.
Jamie 3-27-23 Customer states that condenser is not running. Performed diagnostic and found that condenser is not running due to bad Contactor. Replaced single pole Contactor under parts and labor warranty. Checked system operations and pressures. Recommend having system cleaned. Customer stated that he will call the office if he decides on a membership.
Jessica M.
Peaden installed this 3 zone multi head Daikin mini split back in December of last year and this is our second trip out for the same issue. Upon arrival units were down with only a green indicator blinking light on all 3 indoor heads. We cycled power to all three units after removing panels on outdoor unit to get a visual on the board and other components which there wasn’t anything that could be seen to alert us of a possible issue. We restored power and ran the units for 30 minutes with no problems arising. The pressures were in range and all 3 indoor units were cooling up to manufacturer specifications. I spoke with the homeowner and told her I suspected possible power surge problem as there was nothing else that I could find during diagnostics that would cause the units to behave like they were upon my arrival. I did advise her to contact the power company to run some tests on their end and also gave options for surge protection but said it may not fix the issue but still wanted
James C.
Minor repairs to tankless and other fixtures in home
Chris A.
ChrisA 3-27-23 no cool , nothing turning on when trying to cool Performed diagnostics on system. Checked thermostat & system operations. Cycled system in heat and cool modes. Inspected filter, drain pan and evaporator coil. Tested the drain line and discovered the drain line to be clogged resultin in the ez trap to tripcausing in a loss in 24v to the thermostat. Cleared condensate line and Poc approved. Cleared condensate line and flushed with 1gl water. Checked air flow for supply and return. Acquired amp draws of all components. Found the compressor to be pulling high a,ps on start up. Recommended a hard start kit to reduce the start up amps therefore extending the life of the compressor, customer approved. Installed hard start kit and has now reduced the start up amps. Verified operable and secure before departing. Inspected all wire & wire connections. Checked capacitance of all capacitor’s. Checked safeties. Inspected the condenser coil. Condenser coils are in good shape. Re
Garrett J.
Garrett 3/27/23 Inspected system in heat and cool. Checked amps thoroughly throughout system, inside and out. Checked auxiliary heat for proper and safe operation. Sprayed rinse less cleaner on evap coil. Rinsed condenser coil off with fresh water. Inspected capacitor and contactor, monitored voltage, low and high, through system cycling. Changed filter, cleared condensation line and primed with warm water and chlorine drain tablets.
Lee T.
Lee 3-27-23 One system tune up and inspection Membership status: ESSENTIALS Upon arrival, customer said that ever since the new system was installed that he is having issues with the two far bedrooms properly cooling. I inspected the duct system for any loose connections or kinked flex hoses. I did not see any signs of damage to the ductwork upon inspection. After speaking to management, I will have an appointment scheduled for me and Jason Noyes to come back out here and help me achieve a better diagnosis of the system. For the air handler: Took temperature splits, measured the amps coming into the blower motor, inspected the blower wheel, inspected and cleaned the evaporator coil, flushed the drain line, cleaned the condensation pan, left chlorine tablets inside the condensation pan, tested the float switch if present. replaced the air filter if needed, inspected the thermostat, reset the thermostat to its original setting. For the condenser unit: Measured the capacitor, inspec
Frederick H.
3:07 Get the unit functioning again by replacing the contactor plus repairing the Wires for proper connection. After making the repair I further evaluated the unit and noticed the control board for the condensing geothermal portion Had a flawed Control board with damaged resistors. I need to place the control board on order for replacement and will return for replacement when it arrives. The inside unit has fungus growing inside of it, so I provided options To improve the situation.
Michael A.
Consultation Code: ENGQ7UFPZ
Peaden Air Condition .
Change out gfi customer supplied
Matthew H.
Both gas station bathroom sewer are backed up. Lift station not stopped up. Clean out behind the gas station is holding water. Presented estimate to clear sewer line. Customer declined due to price.
Donovan C.
Electrical inspection Home recently rewired by us. Both panels and all devices and wires are new. Proper power is present in all locations. Smoke detectors are up to date and operate properly Gfci protection is present where needed
Brady C.
Brady 3/27/2023 Arrived with manager to system not blowing. Found very loose connection on blower motor. Tightened connection. Went ahead and got a board. Management is going to handle it from here on. Left system cooling.
Brandon B.
Ran upstairs showers for 15 minutes. Noticed no water coming through first floor ceiling where water damage on wall and ceiling is. Noticed small leak on tub spout where adapter meets the copper stub out piping. Replaced and soldered brass adapter onto copper. Installed new tub spout. Found no other leaks. Showers caulking is good.
Peaden Air Condition .
Upon arrival found system refrigerant low on charge offered customer Lee church found leak on king bow cap time Added 2 pounds of our 410 a installed rm1-12 make the money sitti everything is working properly at this time
Paul B.
Customer opted for furnace and coil only
Jason C.
3/27/23 Jason arrived to elite customer concerns of no cool, ran diagnostic found failed thermostat. Bypassed system to energize reversing valve so the home would cool, however customer wants to call google themselves and attempt to reprogram the thermostat. Set system back to factory settings, built estimates but customer wants to continue with google. Left system down per customer. Service waived by office.
Trey B.
Free estimate for Hvac Replacement (17yr.Age 3.5 Ton Gas Furnace+ 4yr.Age Straight Cool/ Extremely Corroded and Dirty Indoor Evaporator Coils/ Shorted Condenser Thermostat Wires/ Damaged Indoor Blower Motor- Shorted Running Continuously/ Dirty Indoor Fan Motor, Wheel, and Housing/ Mix Matched Hvac systems/ Poor Hvac system Efficiency/ Currently Inoperable/ Due For Replacement/ Outdoor Hvac systems Part Only Warranty Expires (11/24).
Christopher M.
Homeowner Reports issues with Dining Room Light. Dining Room Light Operates via 3 Way Switches. Lights Flicker when 3Way Closest to Kitchen switch is flipped. Removed Switch and verified with Meter, malfunctioning Switch. Provided options for electrical corrections. - Includes Removal of Existing, Damaged 3Way Switch in Dining Room and Replaced with New Device. Includes one year warranty on parts and labor provided by Peaden.
Dennis C.
Plumbing inspection During plumbing inspection, I noticed both lavatory pop-up assemblies in master bath. Need replacing. Also provided upgrade for current washing machine by installing a pure wash system. I noticed upon outside area inspection that there was no hole home water shut off valve. I also provided an estimate to install the shut off valve with a 6 inch round box included. Performed plumbing inspection today. The customer has an electric tankless water heater. No valve kit underneath.
Peaden Air Condition .
Replace outside 200@ service with new overhead service. Tree fell on house. Customer unable to get financing and is living off of social security Price approved by T Owens and J Phillips
Jacob H.
03/27/23 Jacob Performed evaluation on one system, checked amp draws, checked wiring, checked blower wheel, checked temperature splits, checked heat and cool, cleaned coils, cleaned and cleared drain line, replaced filter, checked capacitor. Discovered minor oxidization starting to show on copper lines leading to the outdoor unit, I do highly recommend adding corrosion grenade to help prevent possible corrosion that could happen to copper lines. For the indoor unit, didn’t see any potential issues at this time. System is running properly. Recommend corrosion grenade, and other device that will help with the systems health as in electrically. Customer didn’t approve anything at this time. Left system cooling at 77 degrees.
Charlie B.
Provided estimate to replace a 17 year-old 50 gallon water heater
Remor D.
Rheem RP1424AJ1NA - Classic 2 Ton 14 SEER Heat Pump Condenser, 208-230/1/60 Rheem RH2T2421MEACJA - 2 Ton, Two Stage, EcoNet Enabled, Air Handler, 21" Wide, ECM Motor, EEV Valve, 208/240V, 1Ph, 60Hz
Cameron M.
Issue in piping has caused cable to become stuck. Will need to return with camera . Upon return defect in piping has caused cable to become stuck. We will need to dig up pipe and install cleanouts to access sewer line as sewer line runs 270 ft from unit 7 in attempts to locate and remove cable.