See what our customers say about us
Your opinion is very important to us.
Let us hear what you think about us!
Reviews
Ac inspection
Stephen -
Pace, FL 32571
PaceFL32571 30.64-87.185




Air conditioner service and dryer duct cleaning
Terri -
Panama City Beach, FL 32407
Great service guy!
Panama City BeachFL32407 30.1825-85.8125



Service was excellent.
Jerry -
Panama City, FL 32405
Panama CityFL32405 30.1975-85.6725




Helpful and friendly
Gary -
Pensacola, FL 32504
Chasady was very helpful with a question we had regarding our AC.
PensacolaFL32504 30.48-87.1725



Great customer service
Pat -
Pensacola, FL 32504
Sam is the best!
PensacolaFL32504 30.4675-87.165



Excellent Service
Gary -
Pensacola, FL 32504
Excellent Service! The Service pros were very professional, helpful and friendly. Chasady made sure to answered all of our questions.
PensacolaFL32504 30.48-87.1725



Three foot elevation
Ina -
Lynn Haven, FL 32444
Just a great attitude! Even with the extra work in having to mount my new AC onto a three foot elevated stand🤗
Lynn HavenFL32444 30.2525-85.6525



john
John -
Panama City Beach, FL 32407
great job- good service
Panama City BeachFL32407 30.1875-85.82



Paul explained everything to me where I can understand was very pleasant
Sherry -
Pensacola, FL 32526
PensacolaFL32526 30.4675-87.3




Winder
Len -
Panama City Beach, FL 32413
Great service
Panama City BeachFL32413 30.2875-86.0375



Another great service
Brian -
Navarre, FL 32566
NavarreFL32566 30.4075-86.8175




Gas line repair
Chuck -
Pensacola, FL 32514
PensacolaFL32514 30.5375-87.1975




Gas line repair
Chuck -
Pensacola, FL 32514
PensacolaFL32514 30.5375-87.1975




Good work
Catherine -
Fort Walton Beach, FL 32548
Fort Walton BeachFL32548 30.41-86.5925




Nick is a good tech
Wendy -
Pensacola, FL 32507
Liked Nick . What I don’t like is feeling pressured to buy something they recommend (capacitors, connectors, hard start kits) without researching first. Maybe a grace period on estimate (like 48 hours) that wd help💯
PensacolaFL32507 30.3275-87.3875



Cameron M.
Replace 40 gallon electric water heater Pressure jetting/cleaning sewer main line approximately 50 feet from clean out on back patio Replace wax rings and stop valves to toilets (2) Cameron m 6/1/23: Chip up concrete around cleanout cap and replaced cap in order to inspect sewer system. Once cap was removed it was noted cleanout was holding water. Customer has a lift station with a pump the does not seem to be turning on to pump out waste. It also appears customer may be on septic. Recommend customer to contact health department and determine if on septic or not. Then recommend to have septic and lift station pumped and inspected before proceeding to hydrojetting. Unable to perform hydrojetting till lift station and septic have been pumped and inspected.
David S.
On arrival customer stated that they were aware of the age and conditions of the hvac equipment and just needed it to survive 1 more year. Tuneup On 6/1/2023 tech David Smith arrived to perform the hvac maintenance inspection for the customer. Made all necessary checks to the capacitors, contactors, relays, and wiring connections. All were operating properly and within normal manufacture operating range. Made all necessary checks to the motors and compressor amp draws. All were operating properly and within normal manufacture range. Cleared drain lines, checked coils and filters, removed all debris from condenser cabinet. The indoor blower is clogged with dust and debris, The outdoor coils are corroded badly. The system has a temperature split that is not up to within normal range. Spoke with the customer about the repairs needed, the age, and the options to upgrade to a newer more efficient system. The customer will be reaching out soon to have the equipment upgra
Jacob H.
06/01/23 Jacob Upon arrival customer stated unit is not cooling and making a hissing noise. Discovered evaporator coil has a major leak causing refrigerant to leak throughout part of the indoor unit. System is under warranty until the 11 of December. Customer approved for coil to be ordered. Ordered coil and notified customers it can be in between 2 days to almost a month depending on how fast manufacturer can get it to us. Left system on circulate until coil arrives. Customer has secondary unit for the rest of the first floor section and will be cool until we can get other one cooling.
Peaden Air Condition .
Homeowner no show. Called and left Vm. Left note in door Parker:preformed one system maintenance flushed drain line changed filter tested temp split checked all electrical components system is cooling
Jamaal S.
Mrs. Hill is very pleased with the install
Dennis C.
Whole home filtration system piping adjustment needs to be made. We will be taking the long filter canister that houses the pre filter. This will be the filter located all the way on the right that is inset in the ground. We will adjust the piping so that filter is mounted to the right inside of plastic storage closet that it resides in. Piping appears to be 1” Dispatch will need to reach out to this customer and set up scheduling.
Dangelo B.
Unit tune up and inspection on one unit took temperature splits tested all capacitors and voltages check and changed filter cleared condensation drain line and pan washed outside condenser coils upon inspection discovered microbial growth inside unit condenser unit coils salt corroded compressor pulling high amps upon start up
Herzal A.
Testing/ certifying 1inch back flow device for customer and sending it to the city.
Antwoine G.
Antwoine 6/1/23 Arrived at tuneup Cleaned system Cycled system Checked all system components Checked all system operations Checked all operations on thermostat Checked all operations & components on condenser Checked filters Cleaned drain pan Cleared drain line Rinsed condenser coil Checked temperature split Spoke with customer about system & system enhancements explained to customer how my estimates benefits & prolong life of system customer stated again she will review estimates when she’s free cycled system left systemcooling
Sean D.
10ft spot repair
Charlie B.
Checked water pressure at multiple hose bibs checked water, pressure at kitchen sink faucet as well as multiple fixtures Check water pressure add emergency, stop valves for kitchen sink, faucet, check, water, pressure at multiple hose, bibs and other fixtures within the home
Peaden Air Condition .
Kitchen Sink Waste Repair (MINOR) 1Bowl Tailpiece Minor Repair Kitchen Sink Waste Leak.
Garrett J.
Garrett 6/1/23 Completed elite maintenance. Cleaned furnace, wiped down inside and out of cabinet. Brushed blower out and sprayed rinseless cleaner on coil. Inspected air scrubber. Monitored operations with thermostat in cooling. Checked gas valves and connections. Cleared drain out. Inspected condenser, monitored amps and voltage throughout components. Found condenser capacitor weak, replaced due to being a signature system. Deep cleaned condenser coil, very badly impacted.
Peaden Air Condition .
Ben M. New condensing unit contactor and hard start installed. Operation ok.
Frederick H.
Perform maintenance and evaluation to know the overall condition of the unit. Cleared out the drain system, rinsed the COYLE’s, evaluate the electrical plus refrigeration components for proper operation and safety. It was a good bit of electrical work done to the outdoor unit plus the UV system was installed on the last visit to help prolong the life of the unit. The system is antiquated plus without A warranty. The refrigerant that the unit uses is no longer manufactured. The water heater is from 2005 and has not been flushed in a while. The dryer vent is clean in the homeowner is clear to hook up the dryer.
Zane J.
Inspection of leak turns out to be a leaky faucet and I recommend replacing the whole faucet. Gave three quotes for three different routes. The shut off valves under this particular lav are bad that is included in all 3 quotes.
Alexander M.
Customer showed up to show me work then left right afterward. I gave estimates over the phone.
Chris A.
. ChrisA 6-1-23 water leak 1st floor system Performed diagnostics on system. Checked thermostat functionality and system operations. Cycled system in heating and cooling. Customer pointed out that the bathroom on the first floor nearest the airhandler closet is stained with water on the ceiling coming from the subfloor. Went in the attic and and can see the there’s limited access. Explained to the customer that we will need to cut open the drywall to have better acces to see all of where the condensation is coming from. Appears that from the water stains and how they look that the suction line isn’t properly insulated and needs to be replaced. Inspected evaporator coil and filter. Checked capacitance of all capacitors, found the 45/5 dual run cap not discharging Properly, provided estimate to have replaced. Acquired amp draws of all components. Recommended a hard start kit. Inspected all wire and wire connections. Tested safeties. Inspected condenser coils. Checked pressures and foun
Peaden Air Condition .
We came out today to 84 ton Goodman heat pump system we installed three years ago to do a tuneup. Checked system and heating and air cooling booth checked out great heat strip amps are in range as well as cooling amps. Tightened all electrical connections and wireless at this time. UV system is working properly as it should checked filters filters are clean ordered new filters for home owners. Check capacitor and start amps at this time flushed out condsate pump at this time system is running as should.
Donovan C.
Upon arrival the outlets in all the bathrooms had no power. Upon further examination the tandem breaker controlling this circuit and the gfci in the bathroom closest to the garage have gone bad and will need to be replaced to restore power and continue to provide gfci protection to circuit.
Paul B.
Customer opted for the 26 kw generator
Zachary B.
Came to a no cool call. After arriving I found the float switch was tripped and full of water. The customer stated the system hasn’t been serviced since it was put in 6 years ago. I inspected the whole system and ductwork, I noticed multiple issues going on. Everything is on my summary sheet. The customer wants to do the uv and oxidation bundle and I will do the other option”A” complementary at the same time. She is going to work on getting the money together and get it done. The ductwork is in poor condition and falling apart, the water heater is old and hasn’t ever been flushed, and the customer did ask me about a generator so I added that task in case she decides to explore that option on getting one installed. Thank you for allowing me to check your home today to make sure everything continues to stay working properly for you.
Peaden Air Condition .
Performed a nonmember tuneup on a five year old Peaden pro heat pump system unit is cooling a 22° temperature differential on inspection of the unit found unit had biological growth inside the air handler. Gave customer several recommendations. Also outdoor unit compressor was having a hard time starting After testing all electrical components and checking start amps compressor failed to start starting cap and contactor. Looked good. Recommended customer to add a hard start to the unit to keep the unit from failing upon starting also recommended a coil cleaning on the condenser due to heavy deposits in unit is back cooling and draining properly Vacuum out and flush drain line thoroughly and added tablets to the pan unit is cooling and draining upon departure
Cameron B.
Cameron Beckworth 06/01/23 System no cool customer states condenser is not running. After completing diagnostic discovered bad capacitor not allowing condenser to start. Replaced capacitor with customer approval and while replacing capacitor discovered wiring connections for contactor very poor causing contactor to open and close intermittently. Repaired wiring for a secure connection. Verified system operations, verified amp draws and pressures, Flushed drain and verified temperature differentials. No other issues found left system to tenants preferences cooling upon departure.
Kurt B.
Kurt June 1 Performed a plus member tune up. Checked all components. Found the call contactor hello I can’t hear you hold on call Gypsy well it’s not gonna be this weekend then it’s gonna be in a while. I have to schedule it OK no we’re just gonna walk around on the tarmac this weekend and then we have to schedule the discovery flight for later, go, I’m working, so I start to get pitted, recommended replacing it. I also recommended having coil protectant added to the condenser coil and a whole home surge protector added to the house panel. Customer will consider doing these items on our next visit.